Multifunctional Power Meter — PM 210 / PM 710

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The multifunctional measuring device PM 210 / PM 710, housed in a compact 96 x 96 mm case (with a depth of less than 50 mm), performs all the measurements necessary for electrical installation monitoring.

The large screen allows simultaneous monitoring of three phases and neutral. It displays large characters (11 mm high), has an anti-glare coating, and is equipped with effective backlighting, ensuring excellent readability even in poor lighting conditions or at unfavorable viewing angles.

Key Features

  • Measures voltage and current and calculates: active power [kW], apparent power [kVA], reactive power [kVAR], consumed energy [kWh], power factor [cos phi].
  • Only 50 mm deep. The multifunctional measuring device PM 210 / PM 710 can be installed in the door of the electrical panel, providing more free space for other equipment.
  • Large backlit display with bar indicators. Simultaneous display of four measurement data ensures prompt direct information provision.
  • Intuitive use. Convenient navigation via context menus.
  • Current and power values, total harmonic distortion (THD), and minimum/maximum values in the basic version. Highly efficient multifunctional measuring device for reliable electrical installation monitoring.
  • Accuracy class 2 for active and reactive energy measurement. Suitable for sub-metering or cost allocation.

Applications

  • On-site measurements
  • Sub-metering / cost allocation
  • Remote electrical installation monitoring
  • Harmonics monitoring (THD)

WARNING, the device is currently discontinued.

  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications
Electrical Characteristics
Measurement Type True RMS values up to the 15th harmonic
In three-phase (3P, 3P + N), two-phase and single-phase
AC networks
Sampling rate: 32 samples per period
Measurement Accuracy  Current and Voltage 0.5 % of reading
  Power 1 % of reading
  Frequency ±0.01 Hz from 45 to 65 Hz
  Active Energy Class 1 according to IEC 61036
  Reactive Energy Class 2 according to IEC 61268
Update Period   1 s
 Voltage Input Characteristics  Measured Voltage  10 - 480 V AC (direct phase-to-phase measurement)
10 - 277 V AC (direct phase-to-neutral measurement)
10 - 1600 kV AC (via external VT)
   Measurement Range   0 - 1.2 Un
  Resistance 2 MΩ (phase) / 1 MΩ (phase-neutral)
  Frequency Measurement Range 45 - 65 Hz
Current Input Characteristics Nominal CT Current Primary Adjustable, 5 - 32,767 A
  Secondary 5 A
  Measurement Range 10 mA - 6 A
  Permissible Overload 15 A continuous
50 A, 10 seconds per hour
120 A, 1 second per hour
  Resistance < 0.1 Ω
  Load < 0.15 VA
Power Supply AC 110 - 415 V AC (±10 %), 5 VA
  DC 125 - 250 V DC (±20 %), 3 W
  Stabilization Time 100 ms at 120 V AC
Outputs RS485 Port 2-wire, up to 19200 baud, Modbus RTU, SELV circuit, 6 kV impulse.
(double insulation)
Mechanical Characteristics
Weight 0.37 kg
Protection Degree IP IP52 for front panel, IP30 for the rest of the enclosure
Dimensions 96 x 96 x 69 mm (enclosure with display)
96 x 96 x 50 mm (behind front panel)
Operating Conditions
Operating Temperature Enclosure -5 ... +60 °C
  Display -10 ... +50 °C
Storage Temperature Enclosure and Display -40 ... +85 °C
Damp Heat Relative humidity 5 - 95 % at 50 °C (non-condensing)
Pollution Degree 2
Installation Category III, for networks up to 277/480 V
Electrical Strength According to EN 61010, UL508
Electromagnetic Compatibility 
Electrostatic Discharge Immunity  Level III (IEC 61000-4-2)
Radio Frequency Electromagnetic Field Immunity Level III (IEC 61000-4-3) 
Nanosecond Pulse Interference Immunity Level III (IEC 61000-4-4) 
Microsecond High-Energy Pulse Interference Immunity Level III (IEC 61000-4-5) 
Conducted Disturbances Induced by Radio Frequency Electromagnetic Fields Immunity Level III (IEC 61000-4-6) 
Industrial Frequency Magnetic Field Immunity Level III (IEC 61000-4-8) 
Voltage Supply Dynamic Changes Immunity Level III (IEC 61000-4-11) 
Induced and Radiated Disturbances CE for commercial environment / FCC, part 15, class B, EN 55011
Current Harmonic Emission

IEC 61000-3-2

Voltage Fluctuations IEC 61000-3-3
Safety
Europe CE, according to IEC 61010-1
USA and Canada UL508
Data Transmission
RS485 Port 2-wire, up to 19200 baud, Modbus RTU, SELV circuit, 6 kV impulse.
(double insulation)
Display Characteristics
Dimensions 73 x 69 mm Liquid crystal display with green backlight
(6 lines, simultaneous display of four values)
Built-in Software Features
Min./Max. Values Minimum and maximum values for three phases with indication
phases for voltage, current, and total harmonic distortion
(THD). Minimum and maximum values of the power factor,
total power (P, Q, S), and frequency

Four-wire connection with 3 CTs, without PT

Three-wire connection with 2 CTs and 2 PTs

Send request

Request a callback