CO2 concentration converter with two relay outputs and Ethernet. — H5524

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

CO2 concentration converter with Ethernet interface. Equipped with two relay outputs for signaling, indication, or control of external devices. Each relay includes settings for delay, hysteresis, and sound signal. Parameters are easily adjustable using a computer or the control buttons on the device. The sensor is controlled by a microprocessor housed in a durable plastic case with connection terminals. The large two-line LCD display is designed to simultaneously show two parameters. The display can be turned off if necessary.

Recently, the level of carbon dioxide is considered one of the most important parameters responsible for indoor climate quality. Especially in buildings and rooms with large gatherings of people, such as conference halls, hospitals, schools, cinemas, theaters, and wellness centers.

With the help of CO2 sensors, engineers, environmental experts, and healthcare specialists can optimize ventilation to create a comfortable and "Healthy" indoor climate.

ATTENTION, the device is currently discontinued.

  • Specifications
  • Overall Drawing
  • Electrical diagram
  • Applications

Sensor

H5524

Power supply voltage / power consumption during normal operation / max. power consumption

9 – 30Vdc / 1W / 4W

Relay outputs - max. voltage / max. current / max. power

50V / 2A / 60VA

Ethernet

Yes

CO2 concentration measurement range

from 0 to 2000 ppm

Optionally, the range can be extended

5000 ppm, 10000 ppm

CO2 concentration measurement accuracy at 25oC and 1013 hPa

± (50ppm + 2% of the measured value)

Additional temperature error from 0 to 500C

2 ppm CO2/°C

Recommended calibration interval

5 years

Sensor protection class

IP30

Operating temperature range of the sensor with built-in sensor

from -30 to +60°C

Operating humidity range (without condensation)

from 5 to 95% RH

Operating pressure range

from 850 to 1100 hPa

Measurement interval

15 s

Number of relay outputs

2

Resolution

1 ppm

Sensor position during installation

Cable entry upwards

Storage temperature range (from 5 to 95% RH, without condensation, atmospheric pressure from 700 to 1100 hPa)

From – 40 to + 60°C

Electromagnetic compatibility

EN 61326-1, EN 55011

Weight

330 g

Warranty

3 years

Connection diagram using a power adapter

Connection diagram with power supply via Ethernet cable using a PoE splitter

Connecting the relay to the sensor outputs

    Send request