High-precision piezoresistive pressure transducer, 0.1% FSO — 23SX

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The 23SX series pressure sensors were developed for industrial applications where special requirements for measurement accuracy and stability are demanded.

In this series, temperature dependence and nonlinearity are compensated with high precision thanks to the mathematical model embedded in the sensor electronics. In addition to the RS485 interface with Modbus RTU protocol, this device offers an option for outputting a scalable analog signal via a built-in digital-to-analog converter. The fully welded design without internal seals is suitable for applications with dynamic pressure. Only stainless steel is in contact with the measured medium.

Features

  • RS485 interface possible together with analog interface
  • Analog interface can be reconfigured or disabled via RS485 interface
  • Modbus RTU protocol for measurements, configuration, zero and span adjustment
  • Excellent long-term stability

Technical Solutions

  • Isolated and hermetically sealed piezoresistive pressure sensor
  • Fully welded design without internal seals
  • High-quality pressure sensors and proven mathematical compensation
  • Based on the well-known 33X series technology with the highest level of accuracy

Applications

  • Engine testing on test benches
  • Industrial applications
  • Automation technology
  • Mobile hydraulics

Options

  • Other compensated pressure ranges
  • Other compensated temperature ranges within -40…125°C
  • Other electrical connections
  • Wetted parts made of Hastelloy C-276, Inconel 718, or Titanium
  • Sealing rings made of other materials
  • Other types of oil filling for pressure sensors: e.g., special oils for oxygen applications, hydrogen
  • Vacuum-optimized version for operating pressure ≤ 0.1 bar abs.
  • Integration of internal calculations for special applications
  • Customization for special customer applications
  • Electrical connections:
    • M12 connector (5 pins)
    • Binder 723 connector (5 pins)
    • Cable gland
    • GSP EN 175301-803-A (without RS485)
  • Specifications
  • Overall dimensions drawing
  • Applications

Specifications

Pressure
Accuracy at room temperature (20…25°C) ≤ ± 0.1% FSO Option: ≤ ± 0.05% FSO Linearity (best fit straight line), pressure hysteresis, repeatability, zero offset, gain factor
Total error (-10…80°C) ≤ ± 0.25% FSO Maximum deviation within compensated pressure and temperature range.
Experience shows that outside the compensated temperature range, the total error within the ambient temperature range increases by 0.1% FSO.
Compensated temperature range -10…80°C Option: Other additional temperature ranges possible within -40…125°C
Long-term stability ≤ ± 0.15% FSO Per year under standard conditions, annual recalibration recommended
Position dependence ≤ ± 1.5 mbar Calibrated in vertical mounting position with downward threaded connection
Resolution 0.002% FSO Digital
Signal stability 0.01% FSO Digital noise-free
Internal measurement frequency ≥ 1800 Hz For version «3-wire + digital (0…10 V, 0…5 V)» > 6000 Hz
Pressure range margin ± 10% Outside the pressure range margin, +Inf / -Inf is displayed. In case of device error, NaN is displayed.
Vacuum resistance For operating pressure ≤ 0.1 bar abs., a version optimized for vacuum is recommended.
Temperature
Accuracy ≤ ± 2°C Temperature is measured on the pressure sensor (silicon chip) located behind the metal separating membrane. Values are valid within the compensated temperature range.
Resolution ≤ 0.01°C
Internal measurement frequency > 10 Hz

Send request

Request a callback

Information sent successfully

Благодарим за обращение.
Ваша заявка будет рассмотрена в рабочее время: