Miniature Differential Pressure Transmitter — IZMERKON DD-10
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The miniature differential pressure transducer IZMERKON DD-10 is a MEMS device based on a silicon microchip.
After automatic temperature compensation, linear correction, signal amplification, voltage conversion, and other types of signal processing, a standardized 4…20 mA and RS485 output or other optional signals are provided.
The device also features protection against voltage spikes and reverse polarity, which enhances product reliability, while system stability and high performance are ensured by using temperature compensation functions and digital calibration.
For pressure transducers of this series, two types of isolation are provided: the first type is used for measuring differential pressure of non-aggressive gases in ranges up to 5 kPa, the second type is suitable for measuring pressure of non-aggressive media in ranges above 5 kPa using stainless steel materials and sealing rings.
Features and Benefits
- Capability to measure differential pressure
- Measurement ranges: -100…0…100 Pa, 500…1000 Pa, 0/2/10…100 kPa
- Allowable overload up to twice the upper measurement limit
- Static pressure up to 100 kPa
- Waterproof electrical connection connector
- Measurement accuracy: ±0.25% FSO / ±0.5% FSO / ±1.0% FSO
- Output signal: 4…20 mA / 0…5 V / 0…10 V / RS485 / I2C
- Response time no more than 3 ms (10…90%)
- Measured media: non-aggressive gases when measuring pressure up to 5 kPa and liquids compatible with stainless steel SS316L and silicon when measuring pressure 5 kPa and above
- Specifications
- Overall dimensions drawing
- Applications
Specifications |
||
| Accuracy (% FSO) | 0.5 | 1 |
| Nonlinearity (% FSO) | ≤ 0.4 | ≤ 0.8 |
| Hysteresis, repeatability (% FSO) | ≤ 0.1 | ≤ 0.2 |
| Long-term stability (% FSO/year) | ≤ 0.5 | ≤ 1 |
| Zero temperature drift (% FSO/°C) | ≤ 0.05 | ≤ 0.08 |
| Sensitivity temperature drift (% FSO/°C) | ≤ 0.05 | ≤ 0.08 |
| Effect of static pressure (% FSO/100 kPa) | ≤ 0.05 | |
| Thermal compensation | 0…50°C | |
| Medium temperature | -40…85°C | |
| Ambient temperature | -40…85°C | |
| Protection rating | IP66 | |
| Atmospheric pressure | 86…106 kPa | |
| Vibration overload | 10 g (at 10…2000 Hz) | |
| Shock resistance | 100 g / 11 ms | |
| Service life | More than 10 million load cycles (within permissible temperature ranges) | |
| Maximum static pressure | No more than 200 kPa (depending on the operating measurement range of the transducer) | |
Electrical connection |
||
| Type | Output signal | Power supply voltage |
| Current (2-wire connection) | 4…20 mA | 12…30 V (DC) |
| Voltage (3-wire connection) | 0…5 V | 6…24 V (DC) |
| 0…10 V | 12…30 V (DC) | |
| I2C | I2C | 3.3…5 V (DC) |
| RS485 (4-wire connection) | RS485 | 5…30 V (DC) |
The specified overall dimensions are standard. When using sensors of a different design to obtain information about the dimensions, please contact the supplier.