Differential Pressure Transmitter — PD-39X
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The PD-39X pressure transmitter is a differential pressure transmitter, featuring the use of two absolute pressure sensors, which allows it to withstand overloads on the differential from both sides. Considering this feature, this sensor is most rationally used for tasks where the measured differential is of the same order as the static (reference) pressure.
By default, the sensors have a digital RS485 output, but can also be equipped with an analog output of choice: 4…20 mA / 0…10 V / 0…2.5 V / 0…5 V / 0.1…2.5 V.
An additional application of this sensor can be simultaneous measurement of pressure in two processes, in which case it is mandatory to use the digital output and obtain 2 pressure signals, 2 temperature signals, and a differential pressure signal.
By default, the sensors have a digital RS485 output, but can also be equipped with an analog output of choice: 4…20 mA / 0…10 V. Through the digital output, in addition to the pressure signal, a temperature signal from the sensor can be obtained, which can be useful for static processes.
Options
- OEM solution - dual sensor with electronics used in the 39X series

- Other pressure ranges
- Electrical connections:
- Binder 723 connector (5 pins)
- DIN 43650 connector (4 pins)
- Cable outlet
- Other threaded connections
- Specifications
- Overall Drawing
- Connection diagram
- Applications
|
Characteristic |
Value |
|
Pressure ranges |
from 0...3 to 0...300 bar |
|
Output signal |
RS485; 4…20 mA / 0…10 V |
|
Basic error |
0.05% FSO |
|
Operating/storage temperature |
-40…100°C |
|
Connection |
G1/4” internal, for each sensor |
|
Electrical connection |
Binder-plug 723 (5 pole) |
|
Material |
Stainless steel 316L |
|
Measurement frequency |
200 Hz |
Total error for the differential pressure sensor:
The total error for the TEB differential pressure sensor (in % of the measurement range) is calculated as follows:

Example:
Measurement range of the absolute sensor = 10 bar
Measurement range of the differential sensor = 4 bar.
TEB (in %FSO) = 0.1 x 10/4 = 0.25%


|
|
RS 485 |
2-wire |
3-wire |
|
Power supply voltage |
8…28 V |
8…28 V |
13…28 V |
|
Output signal |
RS 485 |
4…20 mA |
0…10 V |
|
Accuracy, total (-10...80 °C) |
0.1 %FS |
0.1 %FS |
0.1 %FS |
|
Programming and setting the output signal is carried out via the RS 485 digital interface |
|||
CCS30 Software
Each Keller pressure sensor with a digital output can be connected to a computer to work with convenient and functional software.