Thermal Mass Flow Meter — IZMERKON TM 635

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The IZMERKON TM 635 thermal mass flow meter is used for measuring the flow of dry air, nitrogen, and other non-corrosive gases.

The flow meter is specially designed for measuring mass and volumetric flow normalized to standard conditions in small diameter pipelines in industrial systems and laboratories. Data can be output via an analog 4…20 mA output or through an RS485 (Modbus) interface.

Features

  • No moving parts, no risk of clogging
  • Fast response, high measurement accuracy
  • Online diagnostics function
  • Wide adjustment range, measurement down to 0.1 Nm/s
  • Multiparameter monitoring: flow, temperature, and pressure
  • 4-20 mA and pulse output (optional RS485 communication)
  • Built-in 5000 mAh lithium battery provides 16 hours of measurement (optional)
  • Specifications
  • Overall dimensions drawing
  • Applications

Specifications

Application Monitoring of production processes
Measuring medium Air and non-corrosive gases
Pipeline diameter 8 mm~25 mm
Material Sensitive element Alumina ceramic
Housing Aluminum alloy
Connection thread Aluminum alloy
Shell Nylon +15% fiberglass
Display Nylon +15% fiberglass
Measured parameters Mass flow, volumetric flow (standard conditions). Temperature, pressure optional
Output signal Pulse, max. 10 kHz, 4~20 mA
Power supply 15~32 V (DC) or lithium battery 3.7 V, 5000 mAh
Data transmission interface Modbus-RTU
Protection class IP65
Measuring medium Air and non-corrosive gases
Operating temperature Measured medium: -40~100°C
Ambient environment: -20~60°C
Maximum pressure 1.6 MPa
Response time 100 ms
Accuracy ±1.5% of measurement ±0.3% F.S.
Repeatability ±0.3% of measured value
Pressure measurement range 0~1.6 MPa
Temperature measurement range -40~85°C
Measured temperature accuracy ±1°C

The specified overall dimensions are for reference only and may vary depending on
the configuration. Exact dimensions must be confirmed when ordering.

DN

L (mm)

G

8 160 G1/4”
10 130 G3/8”
15 130 G1/2”
20 160 G3/4”
25 160 G1”