Digital humidity sensor. — Sensors H3431, H3331, H3433
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The converters are equipped with two relay outputs for signaling, indication, or control of external devices, discrete inputs, and the H3431, H3331 sensors with an external probe with cable lengths of 1, 2, 4 m. For each relay, delay settings, hysteresis, and sound signal are included. Parameters are easily configured using a computer or the keyboard on the front panel of the sensor. The converter is controlled by a microprocessor housed in a durable plastic case with connection terminals. The large two-line LCD display is designed to simultaneously display two parameters. If necessary, the display can be turned off.
Recently, temperature and humidity levels have been considered as the most important parameters responsible for the quality of the indoor climate. Especially in buildings and rooms with large gatherings of people, such as conference halls, hospitals, schools, cinemas, theaters, and wellness centers.
With the help of such sensors, engineers, environmental experts, and healthcare specialists can optimize ventilation to create a comfortable and "Healthy" indoor climate.
ATTENTION, the device is currently discontinued.
- Specifications
- Overall Drawing
- Electrical diagram
- Applications
|
Sensors |
N3431 |
N3331 |
H3433 |
|
|
Output signal |
2x Relay + RS485 |
2x Relay + RS232 |
2x Relay + RS485 |
|
|
Temperature |
Range |
-30 to +105°C |
-30 to +125°C |
|
|
Accuracy |
±0.4°C |
|||
|
Relative Humidity (at 5-95% RH and 23°C) |
Range |
0 to 100 %RH |
||
|
Accuracy |
±2.5 %RH |
|||
|
Discrete inputs |
yes |
|||
|
Power supply voltage for sensors |
9 - 30 Vdc |
|||
|
Maximum switchable voltage, current and power by relay output |
50V, 2A, 60VA |
|||
|
Accuracy and range of dew point temperature measurement |
±1.5°C at ambient temp. T<25°C and RH >30% |
|||
|
Accuracy and range of absolute humidity measurement |
±1.5 g/m3 at ambient temp. <250C, range 0 to 400 g/m3 |
|||
|
Accuracy and range of specific humidity measurement |
±2.1 g/kg at ambient temp. T < 35°C |
|||
|
Accuracy and range of specific enthalpy measurement |
±3 kJ/kg at ambient temp. T < 25°C |
|||
|
Accuracy and range of mixture component ratio measurement |
±2.2 g/kg at ambient temp. T < 35°C |
|||
|
Sensor / external sensor protection class |
IP65/IP40 |
|||
|
Sensor operating temperature range |
From -30 to +80°C |
|||
|
External sensor operating temperature range |
-30 to +105°C |
-30 to +125°C |
||
|
Operating humidity range (no condensation) |
0 to 100 %RH |
|||
|
Storage temperature range |
From -30 to +80°C |
|||
|
Recommended calibration interval |
1 year |
|||
|
Dimensions / Weight |
136 x 159 x 45 mm (W x H x D), probe length 88 mm, diameter 18 mm / 420 g |
136 x 159 x 45 mm (W x H x D), probe length 155 mm, diameter 18 mm / 430 g |
||
|
Warranty |
3 years | |||
H3431, H3331

H3433



Power from communication port Power from adapter
Relay connection diagram to sensor outputs