Temperature and humidity converters with RS232, RS485 outputs and an external probe with cable lengths of 1, 2, and 4 m. Designed for measurement in environments with pressure up to 2.5 MPa. Housed in a durable wear-resistant case. The large two-line LCD display is intended for simultaneous display of two parameters. The display can be turned off if necessary. The sensor is protected by a stainless steel mesh. There is an option to adjust the output signal.
Humidity and temperature levels are considered among the most important parameters responsible for indoor climate quality. Especially in buildings and rooms with large gatherings of people, such as conference halls, hospitals, schools, museums, cinemas, theaters, and wellness centers.
With the help of such sensors, engineers, environmental experts, and healthcare specialists can optimize ventilation to create a comfortable and "Healthy" indoor climate.
- Specifications
- Overall Drawing
- Electrical diagram
- Applications
|
Sensors |
T3319P |
T3419P |
||
|
Output signal |
RS232 |
RS485 |
||
|
Temperature |
Range |
-30 to +105°C |
||
|
Accuracy |
± 0.4°C |
|||
|
Relative humidity (at RH 5-95% and at 23°C) |
Range |
0 to 100 % RH |
||
|
Accuracy |
± 2.5%RH |
|||
|
Accuracy and measurement range of dew point temperature |
±1.5°C at ambient temp. T<25°C and RH >30% |
|||
|
Accuracy and measurement range of absolute humidity |
±1.5 g/m3 at ambient temp. <250C, range 0 to 400 g/m3 |
|||
|
Accuracy and measurement range of specific humidity |
±2 g/kg at ambient temp. T < 35°C |
|||
|
Accuracy and measurement range of specific enthalpy |
±3 kJ/kg at ambient temp. T < 25°C |
|||
|
Accuracy and measurement range of mixture component ratio |
±2 g/kg at ambient temp. T < 35°C |
|||
|
Power supply voltage |
9 - 30 Vdc |
|||
|
Sensor / external sensor protection class |
IP65/IP40 |
|||
|
Sensor operating temperature range |
From -30 to +80°C |
|||
|
External sensor operating temperature range |
From -30 to +105°C |
|||
|
Operating humidity range (without condensation) |
0 to 100 %RH |
|||
|
Operating atmospheric pressure range |
Up to 2.5 MPa |
|||
|
Storage temperature range |
From -30 to +80°C |
|||
|
Recommended calibration interval |
1 year |
|||
|
Dimensions / Weight (with 1 m probe length) |
88.5 x 114 x 39.5 mm (W x H x D), probe length 150 mm, probe diameter 18 mm /340 g |
88.5 x 114 x 39.5 mm (W x H x D), probe length 150 mm, probe diameter 18 mm /260 g |
||
|
Warranty |
3 years |
|||