Temperature and humidity converter with relay outputs, Ethernet interface, and discrete inputs. — H3530
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
The converter is equipped with two relay outputs for signaling, indication, or control of external devices. It also has three discrete inputs for connecting external devices such as a smoke detector, motion sensor, etc. Delay settings, hysteresis, and sound signal are enabled for each relay. Parameters are easily configured using a computer or the keypad on the front panel of the sensor. The converter is controlled by a microprocessor housed in a durable plastic case with terminal connectors. A large two-line LCD display is designed to simultaneously show two parameters. The display can be turned off if necessary.
ATTENTION, the device is currently discontinued.
- Specifications
- Overall Drawing
- Electrical diagram
- Applications
|
Sensor |
N3530 |
|
|
Output signal |
2x Relay + Ethernet |
|
|
Temperature |
Range |
-30 to +80°C |
|
Accuracy |
±0.4°C |
|
|
Relative Humidity (at RH 5-95% and at 23°C) |
Range |
0 to 100 %RH |
|
Accuracy |
±2.5 %RH |
|
|
Discrete inputs |
yes |
|
|
Sensor power supply voltage |
9 - 30 Vdc |
|
|
Maximum switchable voltage, current and power by relay output |
50V, 2A, 60VA |
|
|
Accuracy and range of dew point temperature measurement |
±1.5°C at ambient temp. T<25°C and RH >30% |
|
|
Accuracy and range of absolute humidity measurement |
±1.5 g/m3 at ambient temp. <250C, range 0 to 400 g/m3 |
|
|
Accuracy and range of specific humidity measurement |
±2.1 g/kg at ambient temp. T < 35°C |
|
|
Accuracy and range of specific enthalpy measurement |
±3 kJ/kg at ambient temp. T < 25°C |
|
|
Accuracy and range of mixture component ratio measurement |
±2 g/kg at ambient temp. T < 35°C |
|
|
Sensor / external sensor protection class |
IP40/IP40 |
|
|
Sensor operating temperature range |
From -30 to +80°C |
|
|
External sensor operating temperature range |
From -30 to +80°C |
|
|
Operating humidity range (without condensation) |
0 to 100 %RH |
|
|
Storage temperature range |
From -30 to +80°C |
|
|
Recommended calibration interval |
1 year |
|
|
Dimensions / Weight |
136 x 213 x 45 mm (W x H x D), rod length 75 mm, / 360 g |
|
|
Warranty |
3 years |
|

Connection diagram with power adapter

Discrete inputs are not galvanically isolated, the +U terminals are internally connected to the power supply device (the +U terminals provide the same voltage level as the power supply voltage).
Connection diagram with power supply via Ethernet cable using a PoE splitter

Connecting a relay to the sensor outputs