Russian manufacturer
of instrumentation and control equipment
EN

8 (800) 777 18 50

Working hours

  • Monday
    09:00-18:00
  • Tuesday
    09:00-18:00
  • Wednesday
    09:00-18:00
  • Thursday
    09:00-18:00
  • Friday
    09:00-18:00
  • Saturday
    Closed
  • Sunday
    Closed
Survey sheets
Request a quote
  • Monday
    09:00-18:00
  • Tuesday
    09:00-18:00
  • Wednesday
    09:00-18:00
  • Thursday
    09:00-18:00
  • Friday
    09:00-18:00
  • Saturday
    Closed
  • Sunday
    Closed

8 (800) 777 18 50

EN
Request a quote

Temperature and humidity converter with relay outputs, Ethernet interface, and discrete inputs. — H3530

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The converter is equipped with two relay outputs for signaling, indication, or control of external devices. It also has three discrete inputs for connecting external devices such as a smoke detector, motion sensor, etc. Delay settings, hysteresis, and sound signal are enabled for each relay. Parameters are easily configured using a computer or the keypad on the front panel of the sensor. The converter is controlled by a microprocessor housed in a durable plastic case with terminal connectors. A large two-line LCD display is designed to simultaneously show two parameters. The display can be turned off if necessary.

ATTENTION, the device is currently discontinued.

  • Specifications
  • Overall Drawing
  • Electrical diagram
  • Applications

Sensor

N3530

Output signal

2x Relay + Ethernet

Temperature

Range

-30 to +80°C

Accuracy

±0.4°C

Relative Humidity

(at RH 5-95% and at 23°C)

Range

0 to 100 %RH

Accuracy

±2.5 %RH

Discrete inputs

yes

Sensor power supply voltage

9 - 30 Vdc

Maximum switchable voltage, current and power by relay output

50V, 2A, 60VA

Accuracy and range of dew point temperature measurement

±1.5°C at ambient temp. T<25°C and RH >30%
range -60 to +80 °C

Accuracy and range of absolute humidity measurement

±1.5 g/m3 at ambient temp. <250C, range 0 to 400 g/m3

Accuracy and range of specific humidity measurement

±2.1 g/kg at ambient temp. T < 35°C
range from 0 to 550 g/kg

Accuracy and range of specific enthalpy measurement

±3 kJ/kg at ambient temp. T < 25°C
range from 0 to 995 kJ/kg

Accuracy and range of mixture component ratio measurement

±2 g/kg at ambient temp. T < 35°C
range from 0 to 995 g/kg

Sensor / external sensor protection class

IP40/IP40

Sensor operating temperature range

From -30 to +80°C

External sensor operating temperature range

From -30 to +80°C

Operating humidity range (without condensation)

0 to 100 %RH

Storage temperature range

From -30 to +80°C

Recommended calibration interval

1 year

Dimensions / Weight

136 x 213 x 45 mm (W x H x D), rod length 75 mm, / 360 g

Warranty

3 years

 

Connection diagram with power adapter

Discrete inputs are not galvanically isolated, the +U terminals are internally connected to the power supply device (the +U terminals provide the same voltage level as the power supply voltage).

Connection diagram with power supply via Ethernet cable using a PoE splitter

Connecting a relay to the sensor outputs

Send request

Request a callback

Information sent successfully

Благодарим за обращение.
Ваша заявка будет рассмотрена в рабочее время:
Пн-Пт с 9 до 18 по московскому времени.