Temperature, humidity, and CO2 concentration converters with RS232, RS485 interfaces, two relay outputs, and remote probe. — Sensors H6321 and H6421
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
Temperature, humidity, and CO2 concentration converters with RS232, RS485 interfaces and remote probe with various cable lengths (1, 2, 4m). Equipped with two relay outputs for signaling, indication, or control of external devices. Delay, hysteresis, and sound signal settings are included for each relay. Parameters are easily adjustable using a computer or with the control keyboard. The converter is microprocessor-controlled, housed in a durable plastic case with terminal connectors. A large two-line LCD display is designed for simultaneous display of two parameters. The display can be turned off if necessary.
Recently, levels of carbon dioxide, temperature, and humidity are considered as the most important parameters responsible for indoor climate quality. Especially in buildings and rooms with large gatherings of people, such as conference halls, hospitals, schools, cinemas, theaters, and wellness centers.
With the help of such sensors, engineers, environmental experts, and healthcare specialists can optimize ventilation to create a comfortable and "Healthy" indoor climate.
ATTENTION, the device is currently discontinued.
- Specifications
- Overall Drawing
- Electrical diagram
- Applications
|
Sensors |
H6321 |
H6421 |
|
Outputs |
RS232 |
RS485 |
|
Measured values |
CO2 + Relative Humidity + Temperature |
|
|
Measured temperature range |
from -30 to +105°C |
|
|
Relay output |
Yes |
|
|
Discrete input |
No |
|
|
LCD display |
Yes |
|
|
PoE |
No |
|
|
Max. switchable voltage, current and power by relay output |
50V, 2A, 60VA |
|
|
CO2 measurement range |
from 0 to 10000ppm (optional 2000 ppm, 5000 ppm) |
|
|
CO2 concentration measurement accuracy |
±100ppm +5% of measured value at 25°C and 1013hPa |
|
|
Relative humidity measurement range |
from 0 to 100% |
|
|
Relative humidity measurement accuracy |
±2.5% at relative humidity from 5 to 95% and at 23°C |
|
|
Temperature measurement accuracy |
±0.4°C |
|
|
Available temperature units |
Celsius, Fahrenheit |
|
|
Dew point temperature measurement accuracy and range |
±1.5°C at ambient temp. T<25°C and RH>30% |
|
|
Absolute humidity measurement accuracy and range |
±1.5g/m3 at ambient temp. T < 25°C |
|
|
Specific humidity measurement accuracy and range |
±2g/kg at ambient temp. T < 35°C |
|
|
Mixture component ratio measurement accuracy and range |
±2g/kg at ambient temp. T < 35°C |
|
|
Specific enthalpy measurement accuracy and range |
±3kJ/kg at ambient temp. T < 25°C |
|
|
CO2 measurement interval |
15 sec |
|
|
Operating temperature range CO2 probe / RH+T probe |
from -30 to +60°C / from -30 to +105°C |
|
|
Filtering capability of sensor housing mesh |
0.025mm – stainless steel mesh |
|
|
Protocol |
ModBus RTU and Advantech ADAM compatible protocol |
|
|
Protection class sensor / CO2 probe / RH+T probe |
IP65 / IP65 / IP40 |
|
|
Power supply voltage |
9-30 V DC, power consumption approximately 1W |
|
|
Dimensions |
136 x 136 x 45 mm (W x H x D) |
|
|
Weight without probe / with 1m / 2m / 4m probe |
360 / 520 / 590 / 730g |
|
|
Warranty |
3 years |
|



Connecting the relay to the sensor outputs