Ammonia Concentration Converter — E2618-NH3-E

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The ammonia concentration converter E2618-NH3 is a representative of the new line of multifunctional measuring instruments PluraSens®.

The device is designed for ammonia monitoring in refrigeration equipment, warehouses, etc. It is not recommended to use the device in rooms with constantly high ammonia concentration (such as livestock and poultry rooms), as this reduces the sensor's service life. For air quality control in such rooms, see E2618-NH3-S.

The device is equipped with a fully calibrated next-generation electrochemical sensor with temperature compensation, ensuring high stability and reliability of readings, as well as a long service life of the device.

To connect the converter to building safety and automation systems, two analog outputs and an RS485 interface operating with the Modbus RTU protocol can be used.

Advantages

  • Metal oxide or electrochemical sensor
  • Detection range 0...100, 0...300, 0...1000 ppm NH3
  • Wall-mounted or duct housing
  • Resolution 1 ppm NH3
  • 2 × 4-20 mA / 0-10 V, RS485

WARNING, the device is currently discontinued.

  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications
Specifications
Calibration Ammonia NH3
Sensor type Electrochemical
Detection method Diffusion
Measurement range

0...100 ppm
0...300 ppm
0...1000 ppm

Overload limit

200 ppm
500 ppm
1500 ppm

Resolution 1 ppm
2 ppm
5 ppm
Signal update every second
Response time T90 < 40 sec
< 40 sec
< 60 sec
Service interval 6 months
Sensor lifetime <2 years
Self-diagnosis Full functionality check at startup
Warm-up time ≤ 1 min
Power supply 11...30 V DC
Power consumption < 2 VA
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, configurable
Housing Light gray ABS plastic, IP65 protection rating
Dimensions 82 × 80 × 55 mm
Remote probe Protection rating IP20,
Standard cable length 3.0 m
Application areas Industrial premises, outdoor use
Operating conditions -40..+50 °C, 15...90 %RH;
Atmospheric pressure ±10%; not for
explosive zones; 
Non-aggressive environment
Note. Do not use the device in places with
constantly high ammonia concentration, such as
livestock farms.
Display (optional)
Operating temperature 0...+50 °C
Display size 72 × 36 mm
Number of characters 3.5 7-segment
Character height 14 mm
Other features Backlight