Oxygen Concentration Converter — E2618-O2

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The oxygen concentration transmitter E2618-O2 is a representative of the new line of multifunctional measuring instruments PluraSens®.

The transmitter is designed to prevent dangerous decreases in oxygen concentration in rooms. In addition, the transmitter can be used to monitor the absence of oxygen in gas mixtures (for example, when working in an inert gas environment).

The device is equipped with a fully calibrated next-generation electrochemical sensor with temperature compensation, which ensures high stability and reliability of readings, as well as a long service life of the device.

To connect the transmitter to alarm, ventilation, and building automation systems, two analog outputs and an RS485 interface operating via the Modbus RTU protocol can be used.

Advantages

  • Accurate stable measurement
  • Wall-mounted or duct version
  • Remote probe (optional)
  • 2 configurable analog outputs 4-20 mA or 0-10 V, Digital RS485 Modbus RTU output
  • Display version available
  • Reliable durable electrochemical sensor
  • Detection range 0...25 vol.% O2
  • Resolution 0.01 vol.% O2
  • Attached or remote sensor
  • 2 × 4-20 mA / 0-10 V, RS485

ATTENTION, the device is currently discontinued.

  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications
Specifications
Calibration Oxygen O2
Sensor type Electrochemical cell
Detection method Diffusion
Measurement range

0...25 %vol. O2

Overload limit

30 %vol. O2

Resolution 0.01 %vol. O2
Nonlinearity < 0.2 %vol. O2
Signal update every second
Response time T80 ~15 seconds
Maintenance interval 6 months
Sensor lifetime <2 years
Self-diagnostics Full functionality check at startup
Warm-up time ≤ 1 min
Power supply 11...30 V DC
Power consumption < 2 VA
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, configurable
Housing Light gray ABS plastic, protection rating IP65
Dimensions 82 × 80 × 55 mm
Remote probe Protection rating IP20,
Cable length standard 3.0 m
Application areas Industrial premises, outdoor use
Operating conditions -30..+50 °C, 15...90 %RH;
Atmospheric pressure ±10%; not for
explosive zones; 
Non-aggressive environment
Note: The sensor may exhibit significant
sensitivity to highly oxidizing gases (e.g.,
ozone, chlorine) at high concentrations
Display (optional)
Operating temperature 0...+50 °C
Display size 72 × 36 mm
Number of characters 3.5 7-segment
Character height 14 mm
Other features Backlight