Sulfur Dioxide Concentration Converter — E2618-SO2

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The sulfur dioxide concentration converter E2618-SO2 is a representative of the new line of multifunctional measuring instruments PluraSens®.

The converter can be used in food and paper industry enterprises, water treatment plants, laboratories, etc.

The device is equipped with a fully calibrated latest generation electrochemical sensor with temperature compensation, which ensures high stability and reliability of readings, as well as a long service life of the device.

Two analog outputs and an RS485 interface operating with the Modbus RTU protocol are used to connect the converter to building safety and automation systems.

Advantages

  • Accurate and stable measurement
  • Wall-mounted or duct version
  • Remote probe (optional)
  • 2 configurable analog outputs 4-20 mA or 0-10 V
  • Digital RS485 Modbus RTU interface
  • Display version available

ATTENTION, the device is currently discontinued.

  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications
Specifications
Calibration Sulfur Dioxide SO2
Sensor Type Electrochemical
Detection Method Diffusion
Measurement Range

0...20 ppm

Overload Limit

150 ppm

Resolution <0.1 ppm
Signal Update every second
Response Time < 30 sec
Maintenance Interval 6 months
Sensor Lifetime > 2 years
Self-Diagnostics Full functionality check at startup
Warm-up Time ≤ 1 min
Power Supply 11...30 V DC
Power Consumption < 2 VA
Digital Interface RS485, Modbus RTU protocol
Analog Outputs 2 × 4-20 mA / 0-10 V, configurable
Housing Light gray ABS plastic, protection rating IP65
Dimensions 82 × 80 × 55 mm
Remote Probe Protection rating IP20,
Cable length standard 3.0 m
Application Areas Industrial premises, outdoor use
Operating Conditions -30..+50 °C, 15...90 %RH;
Atmospheric pressure ±10%; not for
explosive zones; 
Non-aggressive environment
Note. The sensor may show higher
sensitivity to nitrogen dioxide, chlorine, ethylene,
acetylene.
Display (optional)
Operating Temperature 0...+50 °C
Display Size 72 × 36 mm
Number of Characters 3.5 7-segment
Character Height 14 mm
Other Features Backlight