Oxygen Concentration Deficit Converter — E2618-O2-L

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

Description

Oxygen Concentration Transmitter E2618-O2 L is a representative of the new line of multifunctional measuring instruments PluraSens®.

The transmitter is designed to prevent dangerous drops in oxygen concentration in rooms. In addition, the transmitter can be used to monitor the absence of oxygen in gas mixtures (for example, when working in an inert gas environment).

The device is equipped with a fully calibrated latest generation optical sensor, which ensures high stability and reliability of readings, as well as a long service life of the device.

To connect the transmitter to alarm, ventilation, and building automation systems, two analog outputs and an RS485 interface operating with the Modbus RTU protocol can be used.

Advantages

  • Accurate stable measurement
  • Fluorescence-based sensor
  • Wall-mounted or duct version
  • Remote probe (optional)
  • 2 configurable analog outputs 4-20 mA or 0-10 V, Digital RS485 Modbus RTU output
  • Display version available
  • Reliable durable optical sensor
  • Detection range 0...25 vol.% O2
  • Resolution 0.01 vol.% O2
  • Attached or remote sensor
  • 2 × 4-20 mA / 0-10 V, RS485

ATTENTION, currently the device is discontinued.

resource.id|url:['scheme'=>'full']}">
  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications
Specifications
Calibration Oxygen O2
Sensor type Optical
Detection method Diffusion
Measurement range

0...25 %vol. O2

Resolution 0.01 %vol. O2
Signal update every second
Response time ~30 seconds
Sensor lifetime >5 years
Self-diagnostics Full functionality check at startup
Warm-up time ≤ 1 min
Power supply 11...30 V DC
Power consumption < 2 VA
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, configurable
Housing Light gray ABS plastic, IP65 protection rating
Dimensions 82 × 80 × 55 mm
Remote probe Protection rating IP20,
Cable length standard 3.0 m
Applications Industrial premises, outdoor use
Operating conditions -30..+50 °C, 15...90 %RH;
Atmospheric pressure ±10%; not for
explosive zones; 
Non-aggressive environment
Display (optional)
Operating temperature 0...+50 °C
Display size 72 × 36 mm
Number of characters 3.5 7-segment
Character height 14 mm
Other features Backlight