OEM CO2 Content Sensor for High Concentrations — BLG

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

CO2 Engine ® BLG series sensors, designed to measure and store data on environmental conditions such as:

  • Temperature
  • Relative humidity
  • CO2 concentration (up to 30%).

The CO2 Engine ® BLG sensor module is designed to operate on battery power and consumes low amounts of energy, which nevertheless does not affect the accuracy and resolution of measurements.

Virtual RTC (Real-Time Clock) allows storing measurement results and events along with the time. Events include sensor power-on, start and stop of recording, automatic ABC calibration, as well as user-performed zero calibration and background calibration.

Data reading from the logger via I2C connector and using the I2C–USB bridge (SADK, SenseAir accessory).

Data reading for embedded modules via I2C or UART.

 

  • Specifications
  • Applications

Specifications

General Information

Storage / Operating Temperature

-40…+70 °C

Storage Conditions

Non-corrosive environment without condensation[1]

Temperature Compensation Range

0…+50 °C

Operating Humidity Range

0…95% RH relative humidity (no condensation)[2]

Operating Environment

Non-corrosive environment2. HVAC systems of residential, commercial, and industrial buildings[3]

Service Life

> 10 years

Maintenance Interval

No maintenance required. Calibration using ABC algorithm.

Automatic Diagnostics

Full sensor functionality check

Standards Compliance

RoHS directive 2011/65/EU

Electrical / Mechanical Characteristics

Power Supply

Maximum load 4.75-12 VDC[4], stabilized within 10% of sensor power via Vbat+

Maximum load 5.5-12 VDC4, stabilized within 10% of sensor power via G+ (on board protection circuits)

Current Consumption

~250µA (1 measurement per hour)

~50µA in sleep mode

Average ~60 mA during active measurements (~12 s)

Peak value < 150 mA (averaged during infrared signal activation, 100 ms)

Peak value < 250 mA (during infrared lamp activation, first 50 ms)

For maximum operating time (battery powered), use batteries capable of delivering 250 mA pulses without significant voltage drop (e.g., batteries recommended for cameras)

Electrical Connection

Vbat+, G+ and G0

Dimensions (mm)

51 x 57 x 14 (Length x Width x Height) (for 0…30% range)

CO2 Concentration Measurement

Measurement Principle

Non-dispersive infrared (NDIR) with automatic calibration ABC algorithm

Sampling Method

Diffusion

Response Time (T1/e)

Gas diffusion time <25 sec

Measurement Interval

Interval from 5 min to 0.5 years, shorter than 5 min possible but accuracy of humidity and temperature measurement is not guaranteed

Reproducibility

± 0.1%vol. CO2 ± 2 % of measured value

Accuracy[5]

± 0.2%vol. CO2 ± 3 % of the measured value

Pressure dependence

When deviating from atmospheric pressure (100 kPa) – deviation + 1.6 % of the measured value per 1 kPa

Built-in calibration

Din1 relay input, enabling background calibration at 400 ppm (0.04%vol) CO2

Din2 relay input, enabling zero calibration at 0 ppm CO2

Temperature measurement

Sensor

SHT11 by Sensirion (www.sensirion.com)

Measurement range

-40…+60°C

Accuracy[6], [7]

± 0.4°C at 25°C

Relative humidity measurement

Sensor

SHT11 by Sensirion (www.sensirion.com)

Measurement range

0…100% relative humidity

Accuracy[6], [7]

± 3% relative humidity

Data logger properties

Logger memory capacity

5400 data points when recording CO2 concentration, temperature, and humidity (including measurement time information)

Logged parameters

Selectable, one record can contain up to 14 bytes (maximum 4 variables)

Logging interval

(1…255) * Measurement interval

Delay after jumper switch

From 0 to 255 seconds (default – 5s)



[1] Except environments with high SO2 content.

[2] 100% of sensors are tested during production at 45°C / 85% RH / 1000ppm CO2 for one hour. For information on sensor use in high humidity environments, contact SenseAir.

[3] Various optional versions exist for specific applications. Contact SenseAir for more details.

[4] Note that the maximum load is 14V, so the sensor can be used with 12V±10% power supply.

[5] Accuracy defined for operating temperatures and atmospheric pressure of 1013 mbar. Certified calibration gas mixtures are used for calculation. Calibration gas deviation (currently ±2%) is included in the stated accuracy.

[6] Data provided by Sensirion