Mobile data logger — DS 500 PM Mobile
Available on request
Delivery across Russia
Order phone: +7(800)777-18-50
Description
In addition to performing standard measurements of compressed air flow or humidity, this versatile mobile device can handle more complex measurement tasks. Using the DS 500 PM mobile device allows easy analysis of energy efficiency in accordance with the DIN ISO 50001 standard.
The device's clear and simple operation method enables, for example, the analysis of compressed air production costs simultaneously with measuring energy consumption (kW/kW·h) and compressor power (m3/m3/h). The data logger with a built-in active power meter is ideal for conducting audits or maintenance services.
Special Advantages:
- Magnetic probe tips for voltage measurement during operation
- Split-core current transformers can be installed on phase conductors L1, L2, L3 and can also be used during operation
- Ability to connect up to 11 devices, including third-party devices, as well as sensor power supply
- All measurement results are reliably stored in the device memory and easily read via USB drive
- Specifications
- Applications
Specifications |
|
| Case dimensions | 360 x 270 x 150 mm |
| Weight | 4.5 g |
| Material | Cast metal, polyester (display), ABS |
| Sensor inputs |
3/7/11 freely configurable inputs for analog and digital sensors (see options) |
| Sensor power supply voltage | 24 V (DC), max. 130 mA per sensor, built-in power supply max. 24 V (DC), 25 W. For version with 8/12 sensor inputs - 2 built-in power supplies max. 24 V DC, 25 W. |
| Interfaces | USB drive, Ethernet / RS 485 Modbus RTU / TCP, SDI, other interfaces on request, optional Web server |
| Memory card | Micro SD, 16 GB |
| Power supply | 100…240 V (AC), 50-60 Hz |
| Display | Color TFT 7" touchscreen, displays graphs, curves, statistics |
| Accuracy | See sensor specifications |
| Operating temperature | 0…50 °C |
| Storage temperature | -20…70 °C |