Thermal Mass Flow Meter — IZMERKON TM 470

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The IZMERKON TM 470 thermal mass flow meter is an excellent solution for critical industrial applications. It is ideal for measuring compressed air flow and monitoring various gases.

A distinctive feature is the absence of moving parts. The flow meter does not require additional temperature and pressure measurements. Installation can be done quickly and effortlessly.

By default, the flow sensor is equipped not only with analog and pulse outputs but also with a digital RS485 (Modbus-RTU) interface and HART protocol.

Advantages:

  • no moving parts in the sensor design;
  • minimal resistance (pressure drop) after the sensor due to its compact size;
  • wide measurement range with high accuracy;
  • good vibration resistance and long service life;
  • easy installation and simple maintenance of the flow meter;
  • obtaining air and gas flow values normalized to "standard" conditions (no correction for pressure and temperature of the measured medium is required).
  • Specifications
  • Overall dimensions drawing
  • Connection diagram
  • Applications

Specifications

Measuring medium Air, various gases, gas mixtures
Minimum pipeline diameter DN 10
Gas flow velocity measurement range 0.1…100 m/s
Accuracy ±1.0% of measured value (insertion type)
±1.5% of measured value (immersion type)
Operating temperature -40…+220°C (measured medium)
-20…+70°C (ambient)
optional -40...+70°C
Operating pressure For immersion flowmeters and insertion with
Tri-clamp connection: ≤1.6 MPa
For insertion flowmeters with flange and threaded connection: ≤4.0 MPa
Power supply 24V DC or 220V AC, power consumption ≤19 W
Response time 1 s
Output signals 4…20 mA (maximum load 500 Ohm)
pulse output
RS 485 (Modbus RTU)
HART protocol
Relay output/alarm output 1-2 linear relays
normally open state
10A/220V/AC or 5A/30V/DC
Process connection Immersion type installation
Insertion type with flange/threaded/Tri-clamp
connection
Design Compact design
Remote version (default cable length: up to
10 m, optional: up to 100 m)
Pipeline material Carbon steel, stainless steel, plastic, etc.
Display 4-line LCD display (shows current flow, accumulated flow, and other parameters)
Protection rating IP65