Thermal Mass Flow Meter — IZMERKON TM 650

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

To measure the mass flow of air and gases, the IZMERKON TM 650 flow meter uses the principle of thermodiffusion.

The primary converter of the flow meter consists of two thermoresistors (RTD). When the medium flows through them, one of the resistors (RH) heats up, and the second (RMG) measures the current temperature of the flow. As the flow velocity increases, more heat is taken away, causing the temperature of the RH resistor to decrease.

Features and Advantages:

  • Measurement of mass flow or flow normalized to standard conditions;
  • Dynamic range of 100:1 within the following limits: 0.3…30 n.m/s, 0.6…60 n.m/s, 0.9…90 n.m/s, 1.2…120 n.m/s, 1.5…150 n.m/s, 1.8...180 n.m/s;
  • No pressure loss, can be installed in pipelines of any shape with a known cross-sectional area;
  • Installation and maintenance can be performed without stopping the line;
  • High-precision data processing system ensuring excellent reproducibility and low flow meter error;
  • Highly efficient power supply device, total current consumption is only 60 mA at 24 V (DC);
  • Thanks to a wide power supply voltage range of 16…32 V, the flow meter is compatible with various electrical equipment;
  • Easy fault detection and troubleshooting with self-diagnosis function;
  • High wear resistance due to the absence of moving parts.
  • Specifications
  • Overall dimensions drawing
  • Applications

Specifications

Measuring medium Air, nitrogen, oxygen, argon, methane, natural gas, biogas, and other dry gases without moisture content
Pipeline diameter DN25…DN2500
Flow velocity range 0.3…30 m/s (normal)
0.6…60 m/s (normal)
0.9…90 m/s (normal)
1.2…120 m/s (normal)
1.5…150 m/s (normal)
1.8...180 m/s (normal)
Accuracy 1.5% of measured value ± 0.5% of full scale
Medium temperature Standard: -40…+150°C
Optional: -40…+250°C; -40…+450°C
Medium pressure Insertion type: 1.6 MPa
Flanged insertion type: 6.3 MPa
Process connection NPT 1" with ball valve
Power supply 85…264 V (AC) or 16…32 V (DC)
Response time 1 second
Output signal Standard: frequency and 4…20 mA
Digital interface Standard: RS485
Optional: HART and 4…20 mA
Displayed data Mass flow, accumulated flow, volumetric flow normalized to standard conditions
Protection degree IP65

The specified overall dimensions are for reference only and may vary depending on the design. Exact dimensions must be confirmed when ordering. The specified overall dimensions are for reference only and may vary depending on the design. Exact dimensions must be confirmed when ordering.

    Send request

    Request a callback

    Information sent successfully

    Благодарим за обращение.
    Ваша заявка будет рассмотрена в рабочее время: