Insertion flow meter for gases and compressed air with digital interface — VA 520

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

Description

The VA 520 insertion gas flow meter uses a proven thermal anemometric measurement principle. The heated sensor is cooled by the airflow passing by it. The degree of cooling, which serves as an indicator of flow, directly depends on the mass of the passing gas. For this reason, no additional temperature and pressure measurements are required. The compact design of the sensor allows it to be used for monitoring any compressed air systems: from compressors to very small devices (diameters from 1/4 to 2 inches). For diameters larger than DN50, it is better to use VA 500 sensors. In addition to compressed air, the VA 520 flow meter can also measure the flow of other gases such as nitrogen, oxygen, CO2, etc. The installation of the gas flow meter can be done quickly and without much effort. A separate advantage is the removable measuring part. It can be easily dismantled for calibration or cleaning without removing the entire insertion section.

Advantages

  • Easy installation
  • Choice of measurement units: m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
  • Compressed air and gas counter up to 1,999,999,999 m³, resettable from the display
  • Analog output 4...20 mA, pulse output (galvanically isolated)
  • Digital interface RS485 (Modbus-RTU)
  • High measurement accuracy, including at low flow rates (ideal for leak detection)
  • Negligible pressure loss
  • Thermal anemometric measurement principle, no additional pressure and temperature measurement required, no moving parts
  • Gas type configurable via software (nitrogen, oxygen, CO2, nitric oxide, argon)
resource.id|url:['scheme'=>'full']}">
  • Specifications
  • Overall Drawing
  • Connection diagram
  • Applications
Characteristic Value
Measurable parameters m³/h, l/min (1000 mbar, 20°C) for compressed air
or Nm³/h, Nl/min (1013 mbar, 0°C) for other gases
Set from display m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min
Measurement principle Calorimetric
Sensor Thermal mass sensor
Measured medium Air, gases
Gases settable from DS400, DS500, PI500 Air, nitrogen, argon, nitrogen oxide, CO2, oxygen
Measurement range See table in specification
Accuracy ± 1.5 % of measured value ± 0.3 % FS
on request: ± 1.0 % of measured value ± 0.3 % FS
Operating temperature -30...80°C
Operating pressure Up to 16 bar
Optionally up to 40 bar
Digital output RS 485 interface, Modbus RTU
Analog output 4...20 mA for m³/h or l/min
Pulse output 1 pulse per m³ or per liter, galvanically isolated
Power supply 24 VDC ± 15 %
Load < 500 Ohm
Housing material Polycarbonate
Measuring section material Stainless steel 1.4301 or 1.4404
Connection thread External thread R 1/4“, R 1/2“, R 3/4“, R 1“, R 1 1/4“, R 1 1/2“, R 2“
Flanges Flanges according to DIN EN 1092-1 standard, with groove or tongue on request

 

Version of the VA 520 gas flow meter with threaded connection:

Version of the VA 520 gas flow meter with flange connection:

Connector A Connector B
Pin Number Pin Color Function
(Connector A)
Function
(Connector B)
Pin 1 brown +VB NC
Pin 2 white RS 485 (A) GND
Pin 3 blue -VB DIR
Pin 4 black RS 485 (B) Pulse
(galvanically isolated)
Pin 5 gray I+
4..20 mA
Pulse
(galvanically isolated)
Designation Comment
-VB Power supply negative 0 V
+VB Power supply positive 12...30 VDC
I + Current signal 4..20 mA – selected measurement
RS 485 (A) Modbus RTU A
Pulse Pulse output for accumulated flow
NC Do not connect to voltage and/or ground. Cut and insulate the contacts
RS 485 (B) Modbus RTU B