Compact flush-mounted flow meter with built-in flow straightener — VA 525

Available on request
Delivery across Russia
Order phone: +7(800)777-18-50

0 RUB

Description

The new VA 525 flow meter is equipped with modern digital interfaces for connection to energy monitoring systems with a compact design. The VA 525 is used in cases where many devices (compressed air consumers) need to be included in the energy monitoring network.

VA 525Display of two values simultaneously:

  • Current flow in m³/h, l/min,...
  • Cumulative flow in m³, l, kg
  • Temperature
  • Optional: pressure

The image on the display rotates 180°, for example, when the device is installed upside down

Threaded connection:

VA 525Easy installation in the pipeline using the built-in measuring section (for diameters 1/4˝, 1/2“, 3/4˝, 1“, 1 ¼˝, 1 ½“ or 2"). 
Thanks to the built-in flow straightener, no straight pipe sections are required before the flow meter

Control using buttons:

  • Reset cumulative flow counter
  • Select units of measurement
  • Interface configuration

Advantages

  • Compact design for installation in systems after the service unit;
  • Analog outputs (4...20 mA, pulse) or digital interfaces: Modbus RTU, Ethernet, PoE, M-Bus;
  • Interface configuration from the device display.
  • Specifications
  • Overall dimensions drawing
  • Applications
Technical Specifications VA 525
Measurable Parameters m³/h, l/min (1000 mbar, 20 °C) for compressed air or Nm³/h, Nl/min (1013 mbar, 0°C) for other gases
Units of Measurement m³/h, m³/min, l/min, l/s, ft/min, cfm, m/s, kg/h, kg/min, g/s, lb/min, lb/h
Measurement Principle Thermal mass flow meter
Measurement Medium Air, nitrogen
Gas Types (selection via software or dataloggers) Air, nitrogen
Measurement Range See table above
Accuracy
(FSD = full scale deflection)
± 1.5 % of measured value ± 0.3 % FSD On request:
± 1 % of measured value ± 0.3 % FSD / ± 6 % of measured value ± 0.5 % FSD
Measured Pressure 0...16 bar, accuracy: 1 % / 10...2000 mbar abs.
Operating Temperature -20...60 °C
Operating Pressure Up to 16 bar
Digital Output RS 485 interface (Modbus RTU), M-Bus (optional), Ethernet or PoE
Analog Output 4...20 mA for m³/h or l/min
Pulse Output 1 pulse per m³ or per l, galvanically isolated. Configuration is done via the display. Can also be used as a signal relay.
Power Supply 18...36 VDC, 5 W
Load < 500 Ohm 
Housing Material Polycarbonate (IP 65) 
Measuring Section Material Aluminum
Connection Thread From G 1/4“ to G 2“ (BSP) or from 1/2“ to 2“ NPT
Installation Position Any

VA 525